ALPHATECH TECHNOLOGIES s.r.o.
Jeremenkova 88, Praha 4, Czech Republic
www.alphatechtechnologies.cz
In order for backlight, heating of the circuit board (to avoid condensation) and to power a
lock, a 12VDC 1A power supply is required. Refer to manual.
There are two options to control external devices e.g. Lock, Light, Bell. Either NO (Normally
Open) or NC (Normally Closed). Refer to wiring diagram below.
Quick Setup
Set the jumper to either peer to peer (without an IP PBX or IP Telco) or
SIP server for the door phone to register against an IP PBX or IP Telco.
The DoorPhone comes with a static IP address of 192.168.1.250 with
username: admin and password: 1234